Building inspection Hilversum: knowledge base
In brief
Premiumkeur Hilversum inspects homes in Hilversum and the rest of ’t Gooi: Bussum, Naarden, Laren, Blaricum, Huizen, Loosdrecht and Kortenhoef, and in Baarn and Soest. We are a branch of Premiumkeur B.V., an independent building consultancy with its head office in Amsterdam (Chamber of Commerce (KvK) 81106130). The Hilversum branch is at Leeuwenstraat 42, 1211 EW Hilversum.
A standard building inspection costs € 499 including VAT for a home up to 800 m³. The inspection takes 1 to 1.5 hours on average. You receive the report within 2 working days. We work to NTA 8060 and are recognised by the National Mortgage Guarantee (NHG) and certified to NEN 2767. We do not work with estate agents.
This knowledge base covers what you need to know as a buyer or owner in this region: the inspection, the costs, cellars and foundations in ’t Gooi, damp, thatched roofs, owners’ associations (VvE) and the purchase agreement. Practical cases from our own reports from Hilversum and the surrounding area follow after that. Premiumkeur has an average of 4.9 stars from 698 Google reviews and 100 Trustpilot reviews.
This page is the English version of our Dutch knowledge base (kennisbank). Reviews that clients wrote in English are on our page English reviews.
1. How a building inspection works
The inspection is a visual check: we look, measure and take photographs, but we do not open anything up. The inspector goes through the house from the roof to the crawl space. This takes 1 to 1.5 hours on average.
What the inspector looks at
- The roof. The inspector goes onto it if that can be done safely and responsibly.
- The crawl space or cellar, if it is accessible: floor joists, moisture content, ventilation, pipes and the visible part of the foundation.
- Façades, cracks and tilt. In older houses we measure bed joints and floors.
- Installations: fuse box, central heating boiler, gas pipe, water, drainage, ventilation and smoke alarms.
What is not included
What we cannot see or reach is stated in the report, with the reason. An asbestos survey is not part of the inspection. If we see suspected asbestos material, we report it. Have a specialist firm investigate it before you sign.
The report
For each building element you receive photographs, a condition score according to NTA 8060, an explanation and a cost indication including VAT. The costs are shown in three columns: needed immediately, within five years and improvements. An inspection is a snapshot of what is visible on that day.
When to call us
Make your offer subject to a building inspection condition (voorbehoud) and call straight after the verbal agreement. The condition usually runs for only a few weeks. If you are present during the inspection, you see for yourself what the inspector sees and you will understand the report better afterwards. It is not compulsory. If you already have a report from another firm and you have doubts, we can carry out a second opinion (contra-expertise), from € 599.
2. Prices in Hilversum and ’t Gooi
All amounts include VAT, as of October 2026. They are the same as the prices of Premiumkeur Amsterdam.
| Service | Price |
|---|---|
| Building inspection | € 499 up to 800 m³, € 0.50 per extra m³ |
| Inspection with foundation quick scan (phase 0) | from € 898 |
| Foundation investigation phase 1 | € 699 to € 1,499 |
| Foundation investigation phase 2 | from € 3,000, excluding excavation |
| Installing monitoring bolts (8 to 10 bolts) | € 1,179 |
| Crawl space inspection | from € 499 |
| Roof inspection | from € 499 |
| Tracing a leak | € 499 to € 599 |
| Tracing a roof leak | from € 599 |
| Damp investigation | from € 499 |
| Damp investigation in the cellar | € 699 |
| Balcony inspection | from € 699 |
| Crack investigation | from € 499 |
| Second opinion or dispute with a contractor | from € 599 |
| Baseline survey (nulmeting) | € 499 |
| Handover inspection, new-build | € 499 |
| Long-term maintenance plan (MJOP) for a VvE (maximum 5 apartments) | € 899 |
What repairs cost
The report gives a cost indication for each defect. For foundation repair we quote a price per m², not a total amount, because the differences between properties are large. Foundation repair costs from € 2,500 per m², with a cellar from € 3,500 per m². The finishing work afterwards costs from € 3,000 per m². Drawings and permit cost € 10,000 on average.
3. Building and living in Hilversum and ’t Gooi
Of the homes we inspect in this region, 68 per cent were built before 1940. Many of them date from the period 1906 to 1930. What stands out to us in the reports from this region:
- Many homes have a cellar or semi-basement (souterrain) (cases 1, 4, 5, 6, 9, 13, 16, 20, 21, 22, 26 and 27). There we often see damp, leaks in the cellar walls, rotten beam ends in the floor above and rusting steel (cases 5, 16, 20 and 26).
- A cellar often sinks less than the walls around it. This causes cracks and tilt around the cellar (cases 13, 21 and 27).
- In our reports, homes in this region often have a shallow foundation (op staal), so without timber piles (cases 12, 21 and 31). In some places there is peat in the topsoil; in Huizen a boring profile showed about 2 metres of peat (case 21).
- Extensions often have a shallower foundation and sink separately from the house (cases 9 and 22).
- We mostly come across thatched roofs on villas and detached houses (cases 7 and 30). With thatch we look at, among other things, the wear layer and the binding wires.
- Some bay windows and cellars contain steel that is rusting. This causes cracks in the brickwork (cases 16 and 19).
4. Foundations
Until about 1970, homes in the Netherlands were often built on timber piles (RVO). The year of construction says something about the type of foundation, but not about its condition. That only becomes clear from measurements. Our advice: for a house built before 1970, have the foundation investigated before you buy.
Signs
Leaning façades, joints that run out of line, cracks above windows and doors, sticking doors and sloping floors. A clear difference from the neighbouring houses is also a sign. Cracks can also have other causes, such as shrinkage, a missing lintel or a subsided extension. Only measurements show whether the foundation is the cause.
The foundation label (funderingslabel)
Since 1 April 2026, every valuation report includes a foundation label from A to E. The valuer determines the label on the basis of visible signs and online data. For class D or E the valuer advises further investigation (Ministry of BZK, 1 April 2026). The label is a risk indication, not a foundation investigation.
Types of foundation investigation
- Quick scan (phase 0): bed joint measurement and floor levelling during the inspection. Together with the inspection from € 898; the quick scan itself then costs € 399.
- Phase 1: more extensive investigation above ground, € 699 to € 1,499, depending on how in-depth the investigation is. Archive research costs extra.
- Phase 2: the foundation is dug out and examined up close. From € 3,000, excluding excavation.
- Monitoring bolts: 8 to 10 bolts for € 1,179. After measuring for 2 to 3 years you know how fast the property is sinking.
Tilt is a snapshot. If a property sinks evenly by less than 1 to 2 mm per year, further investigation is usually not needed. At more than 2 mm per year, phase 1 or phase 2 follows.
Who pays for repairs?
For an apartment the VvE pays, and each owner contributes in proportion. If you share a party wall with the neighbours, you need their permission and you usually share the cost.
More about foundation investigation can be found in the foundation investigation knowledge base.
5. Cellar, crawl space, damp and wood rot
In ’t Gooi, damp is often a cellar problem. Water comes in through the cellar walls or the floor, and the beam ends of the floor above get wet. We also regularly see crawl spaces without ventilation, even in newer homes (cases 8 and 10). For a cellar we often recommend a separate damp investigation; that costs € 699.
How we inspect the crawl space
We go in ourselves and check the floor joists and floorboards for wood rot, fungus and woodworm. We measure the moisture content with calibrated moisture meters; dry wood is around 12 per cent. If the crawl space is lower than 20 cm, we use a crawl space robot with a camera. If there is water, or suspected asbestos material, we do not go in.
Common defects
| Defect | What it is |
|---|---|
| Beam end rot | Rot at the end of floor joists that lie in a damp wall |
| Wood rot | Decay of wood caused by long-term damp |
| Woodworm | Damage by beetles, especially in poorly ventilated crawl spaces |
| Dry rot (huiszwam) | Fungus in very damp, poorly ventilated spaces |
| Rising damp | Damp that rises from the ground into the wall |
| Penetrating damp | Rainwater that comes into the house through the façade |
| Mould | Black patches caused by condensation or too little ventilation |
6. Roof, façade and equipment
We go onto the roof if it is safe to do so. For difficult leaks we use a cherry picker or scaffolding, at extra cost.
What we often see on roofs and façades
- Thatched roofs with a thin wear layer or visible binding wires.
- Tiled roofs and dormers with too little lead overlap.
- Valley gutters and roof gutters that are blocked or leaking.
- Flat roofs and roof terraces with decayed boarding.
- Leaning chimneys and loose window sills that let water into the façade.
Equipment
| Equipment or method | Use |
|---|---|
| Moisture meters | Moisture content of beams, floorboards and walls |
| Bed joint measurement and floor levelling | Measuring tilt and subsidence |
| Endoscope | Looking into flues, cavity walls and closed-off crawl spaces |
| Infrared camera | Making leaks and poor insulation visible |
| Smoke generator | Finding the source of a leak or a smell |
| Hydrogen detector and ultrasonic detection | Leaks in water and central heating pipes |
| Dye test | Leaks in drains |
| Crawl space robot with camera | Crawl spaces lower than 20 cm |
7. Lifespan of building elements
These are guideline values. How long something really lasts depends on quality, location and maintenance.
| Building element | Guideline value |
|---|---|
| Central heating boiler | 12 to 15 years |
| Zinc roof gutter | 20 to 30 years |
| Bituminous roofing | 20 to 25 years |
| EPDM roofing | about 40 years |
| Smoke alarm | maximum 10 years |
| Sealant joints in bathroom and kitchen | renew about every 6 years |
| External paintwork | every 6 to 8 years |
8. Apartments, VvE and long-term maintenance plan
With an apartment you buy a share of the building. Ask for the minutes, the long-term maintenance plan (MJOP), the reserve fund and the annual accounts of the VvE. This is part of your duty to investigate. You request the deed of division with drawing from the Kadaster (Land Registry).
Banks often ask for an MJOP or the annual accounts for apartments. We can draw up an MJOP; for a small VvE (maximum 5 apartments) this costs € 899. Foundation repair to an apartment building is paid for by the VvE.
9. Purchase agreement and duty to investigate
Always make your offer subject to a building inspection condition. If the repair costs exceed the agreed amount, you can dissolve the agreement free of charge.
| Term | What it means for you |
|---|---|
| Duty to investigate | The seller reports defects that he knows about. What you could have seen in a reasonable inspection is usually at your own expense. |
| Dissolving condition, building inspection | The purchase goes ahead only if the repair costs stay below an agreed amount. |
| Threshold amount | Often around € 5,000. It is not compulsory. |
| Statutory cooling-off period | Three days after receipt of the signed purchase agreement (article 7:2 of the Civil Code). |
| Age clause | The home is old and may have defects that come with that. |
| As is, where is | You buy the home as it stands, without guarantees. |
| NHG | Our inspections are NHG-recognised; you can use the report for your mortgage lender. |
10. Choosing an inspector
As a buyer you are free to choose your own inspector. An inspector recommended by an estate agent may have a business arrangement with that agent. So ask whether the inspector pays the estate agent a fee.
In the Netherlands anyone can call themselves a building inspector. What an inspection covers differs from firm to firm and is set out in the general terms and conditions. Read them before you sign. Investigative journalist Bram Logger wrote about this in The small print of home inspectors (Onderzoekscollectief Spit, 10 May 2023).
Questions you can ask any inspector:
- Do you measure the tilt of floors and bed joints?
- Do you go into the crawl space, or do you look from the hatch?
- Do you go onto the roof, or do you look from the ground or a ladder?
- What do your general terms and conditions say about foundation, roof and crawl space?
- Does the estate agent receive a fee if he refers me to you?
Premiumkeur does not accept assignments via estate agents and does not pay for referrals. We also do not recommend contractors or roofers: that way we have no interest at all in who carries out the repair.
11. Specialist investigation and baseline survey
- Dispute with a contractor: we assess the work and write an expert report, from € 599.
- Baseline survey: records the condition of your property before building or demolition takes place, on your side or next door. € 499. In Bussum, for example, we did one next to demolition work (case 25).
- Damp investigation in the cellar: € 699.
- Handover inspection for new-build or after a renovation: € 499.
12. Case studies from Hilversum
These cases come from our own reports, 2022 up to and including 2026. Addresses and names have been left out. Amounts are the estimates from the report, at the price level of that year.
Case 1: House from 1904 that has subsided towards the rear, Hilversum
Situation: Terraced house from 1904, 2 storeys, with cellar, no owners’ association (VvE), occupied. In September 2026 the client had a building inspection with foundation risk assessment carried out.
Findings:
- The front facade is out of level by about 5 mm to the right; a floor levelling survey on the upper floor showed the right side about 16 mm lower and the rear about 45 mm lower than the front. The soil is sand and the ground subsidence is about 0.4 mm per year: foundation risk class C. The roof boarding is affected by damp in places and has no waterproof membrane (improvement € 15,000). The cellar shows a great deal of damp. Suspected asbestos material lies on the shed roof. Total immediate € 5,225, longer term € 2,250 (2026 price level).
Advice: Have a monitoring bolt installed and have it measured every year for at least five years; if the settlement increases, carry out a further foundation investigation. Renovate the roof in due course with a vapour-permeable, waterproof membrane.
What this shows: Where plasterwork makes bed joint measurements impossible, a floor levelling survey can still give an indication of tilt. A measured settlement calls for monitoring, not immediately for foundation repair.
Case 2: Crawl space full of insulation beads and a central heating boiler from 2006, Hilversum
Situation: Terraced house from 1925, 3 storeys, no VvE, occupied. In September 2026 the client had a building inspection with foundation risk assessment carried out.
Findings:
- The crawl space is filled with insulation beads and could only be partly assessed from the hatch; the moisture readings there were acceptable. The central heating boiler dates from 2006 and, according to the sticker, was last serviced in 2020. The fuse box has no main switch. Suspected asbestos material is present at the chimney flues; an old damp mark near the chimney did not give an elevated reading. Ground subsidence about 0.3 mm per year: foundation risk class A. Total immediate € 4,000, longer term € 2,000 (2026 price level).
Advice: For full certainty, have the insulation beads removed in places and the crawl space investigated before the purchase agreement. Have the boiler serviced, the flue gas outlet checked and a main switch installed.
What this shows: Insulation beads in a low crawl space make inspection and later maintenance of pipework difficult. An old damp mark does not have to be an active leak if the reading is dry.
Case 3: Sagging floor without a crawl space hatch in a house from 1951, Hilversum
Situation: Terraced house from 1951, 2 storeys, no VvE, occupied. In September 2026 the client had a building inspection with foundation risk assessment carried out.
Findings:
- There is no crawl space hatch; at the front door, in the living room and in the kitchen the floor, probably timber, sags clearly, and the ventilation openings in the rear facade have been boarded over. Under the balcony the concrete coating has come loose in several places. Around the plastic window frames there are large open joints without a driving-rain seal. The fuse box has no main switch and one earth leakage circuit breaker (replacement € 1,000). Ground subsidence about 0.4 mm per year: foundation risk class A. Total immediate € 5,925, improvement € 20,000 (2026 price level).
Advice: Before the purchase agreement, have an access hatch made and the crawl space investigated. Have the cladding under the balcony removed and the concrete inspected; allow for a financial setback.
What this shows: A low foundation risk does not rule out defects in the floor: the sagging can be in the timber floor itself. A boxed-in underside of a balcony can hide concrete damage.
Case 4: Major maintenance to the roof and paintwork of a house from 1917, Hilversum
Situation: Semi-detached house from 1917, 2 storeys, with cellar, no VvE, occupied. In July 2026 the client had a building inspection carried out.
Findings:
- The tiled roof has reached the end of its economic life: tiles fit poorly, ridge tiles are coming loose and there are emergency repairs with lead between the tiles; full roof renovation € 30,000. The exterior paintwork is very poor (€ 15,000) and the bay window frame must be replaced (window frames in total € 12,500). The upper floor is heated with loose gas heaters (€ 6,500 for extending the central heating). The cellar shows damp marks and the cellar stairs are unsafe. The ground subsidence is about 0.2 mm per year and the foundation risk is low. Total immediate repairs € 90,625 (2026 price level).
Advice: Renovate the complete roof, including gutters and zinc work, in one go, with a vapour-permeable membrane. Before the purchase agreement, have a destructive crawl space investigation carried out, because there is no crawl space hatch.
What this shows: A low foundation risk result says nothing about maintenance: a house can stand firmly and still have a large maintenance backlog. With a worn-out roof, local repair is sometimes no longer sensible.
Case 5: Rotten beam ends above a wet cellar, Hilversum
Situation: Commercial building from 1920 in use as a home, 2 storeys, no VvE, unoccupied. In June 2026 the client had a building inspection carried out, without an additional foundation risk investigation.
Findings:
- The timber upper floor rests on the cellar walls; the ends of several beams are severely affected by wood rot and the floor is temporarily supported. In the cellar the moisture readings exceeded the limit values by a wide margin, in places up to the maximum reading, with a strong smell of mould. The drainage is partly still made of lead and leaked slightly. Total immediate repairs € 14,850, of which € 10,000 for the structural floor and € 1,500 for the drainage (2026 price level).
Advice: Before signing the purchase agreement, have destructive investigation carried out on all beam ends and have a damp specialist investigate the cellar. Replacing only the beams is not durable as long as the cellar walls stay wet.
What this shows: A suspended ceiling or a false wall can hide structural damage from view. Wood rot in beam ends is often linked to damp in the brickwork on which they rest.
Case 6: 1930s end-of-terrace house with cellar without serious defects, Hilversum
Situation: End-of-terrace house from 1932, 3 storeys, fully cellared, no VvE, occupied. In June 2026 the client had a building inspection carried out, including an assessment of the foundation risk.
Findings:
- Slightly elevated moisture readings were measured at the bottom of the cellar walls, possibly due to capillary damp; the false walls were dry and the thermal imaging camera showed no anomalies. In the chimney flue the moisture readings were slightly above the limit value, shortly after work on the chimney. There is no vapour-permeable membrane under the tiles. According to bed joint and plumb measurements, the house is true to within a few millimetres: risk class A. Total immediate repairs € 1,275 (2026 price level).
Advice: Keep monitoring the moisture readings in the chimney and, if they increase, have a chimney specialist take a look. Have exposed wiring in the fuse box repaired and a carbon monoxide detector installed.
What this shows: A cellar in an older house does not have to be a damp problem; measurements and thermal imaging give more to go on there than the year of construction alone. Elevated moisture shortly after repair work can be residual moisture.
Case 7: Worn thatched roof and leaning chimney, Hilversum
Situation: Semi-detached house from 1933 with three storeys and a thatched roof, no VvE. At the client’s request a building inspection was carried out in April 2026, without a foundation risk investigation.
Findings:
- The wear layer of the thatch has diminished and the binding wires are visible; the roof area is estimated at about 360 to 400 m², replacement € 90,000 immediate (2026 price level). The chimney clearly leans: € 5,500 for rebuilding (2026 price level). There is (partly active) woodworm in the roof structure. One moisture reading was above the limit value: active leak. Total € 176,250 immediate and € 60,000 improvement (2026 price level).
Advice: Allow for replacement of the thatch in the short term and have the chimney assessed by a structural engineer or contractor. Before signing the purchase agreement, have leak detection and a crack or foundation investigation carried out.
What this shows: In a house with a thatched roof, a single component can determine the costs: here, more than half of the immediate costs.
Case 8: Damp crawl space without ventilation in a house from 2011, Hilversum
Situation: Terraced house from 2011 with three storeys, no VvE. At the client’s request a crawl space inspection was carried out in February 2026.
Findings:
- The relative humidity in the crawl space was about 81%, whereas 50 to 70% is desirable. There was a lot of condensation on the foundation walls and the underside of the insulation, and mould on the floor. No ventilation grilles were found at the front and rear, and no duct openings inside. Around drains and under the meter cupboard, insulation has been removed, which creates cold bridges. There was also building waste.
Advice: Have at least two ventilation ducts of at least 100 mm installed at the front and rear, restore the insulation at the penetrations and remove the building waste. If that is not enough, fit mechanical ventilation with a moisture sensor and, if necessary, a ground sheet or shells.
What this shows: Even a relatively new house can have a damp crawl space if ventilation provisions are missing.
Case 9: Deferred timber maintenance and sinking extension at an end-of-terrace house from 1905, Hilversum
Situation: Occupied end-of-terrace house from 1905 with two storeys, cellar and extension, no VvE. In June 2025 the client had a building inspection carried out with an additional foundation quick scan (phase 0).
Findings:
- Due to deferred maintenance, window frames, dormers, fascia boards, bargeboards and the gutter boxing have wood rot; replacement of the dormers is budgeted at € 9,000 and new paintwork at € 6,500 (2025 price level). In the loft, active penetrating damp was measured at the side facade. The timber in the crawl space measures almost 17% moisture, above the limit of 12%. The left side of the house has subsided and the rear of the extension is sinking faster, presumably because the cellar does not run under the whole extension. The immediate costs are € 35,325 (2025 price level).
Advice: The report advises a leak detection investigation before signing the purchase agreement and better ventilation of the crawl space. For the foundation, it advises installing monitoring bolts and establishing beforehand whether foundation repair is feasible.
What this shows: Even outside a foundation risk area, on firm sandy ground, a house can settle unevenly, for example if a cellar lies under only part of an extension.
Case 10: Mould caused by a wet crawl space and a cold bridge at a balcony, Hilversum
Situation: Occupied ground-floor end-of-terrace flat in a block of flats from 1957, one storey, with a VvE. Because of black mould and recurring damp patches, a crawl space inspection and damp investigation were carried out in June 2025.
Findings:
- The crawl space under a bedroom is not ventilated; there is a lot of yellow mould on the floor and the walls are saturated by rising damp. Along the facades, wet soil lies against the walls, which causes penetrating damp and condensation. The concrete balcony is not watertight and shows concrete rot. The balcony forms a cold bridge, as a result of which condensation and black mould form on the ceilings. The rainwater pipes are not connected to the sewer.
Advice: The report advises gravel strips along the facades (about 50 cm wide and 50 cm deep at the garden side, 40 cm wide and 50 cm deep at the front and side facades), extra ventilation openings and mechanical ventilation with a moisture sensor in the crawl spaces. In addition, the balconies must be given a waterproof coating on top.
What this shows: Damp problems often have several causes at once. Some can be solved well, but a cold bridge caused by a design error can hardly be remedied.
Case 11: Old wiring and cracks in storage room in a flat from 1958, Hilversum
Situation: Occupied flat from 1958 with two storeys in a building with a VvE. In April 2025 the client had a building inspection carried out, without a foundation quick scan (phase 0).
Findings:
- The home still has old wiring from before the colour coding of the 1970s; € 2,000 is included for improving the electrics (2025 price level). No earthing point was found in the bathroom and floor tiles around the shower sound hollow. The bathroom door is missing (€ 650, 2025 price level). In the storage room there are damp patches and large cracks that may point to a foundation problem. The immediate costs are € 3,100 (2025 price level), of which € 725 for the VvE.
Advice: The report advises having the wiring assessed by a certified electrician before purchase and the earthing checked. The cracks and damp patches in the storage room must be reported to the VvE and investigated further, including the drainage.
What this shows: In a flat within a VvE, some defects, such as earthing and cracks in a storage room, lie with the association and not with the individual owner.
Case 12: Cracks after opening up a load-bearing wall turn out to be foundation-related, Hilversum
Situation: Occupied terraced house from 1934 with two storeys and semi-basement (souterrain), no VvE, on a shallow foundation (op staal). Cracks appeared after an opening was made in a load-bearing wall in 2021; in April 2025 the client had the cause investigated.
Findings:
- At the opening itself, no tilt or settlement of the steel beam was measured. In the semi-basement, 40 mm of settlement over 3530 mm (1:88) and 50 mm over 3530 mm (1:70) were measured, both damage classification ‘structural’. On the ground floor, 47 mm of settlement over 8550 mm (1:181) was measured. The facade crack at the front left falls in the category moderate to large. According to the client, the cracks developed over the past 1.5 to 2 years.
Advice: The report advises monitoring bolts (about € 1,100 to install and € 600 to measure, 2025 price level) and a foundation investigation phase 2. In addition, it advises having the opening checked by a structural engineer’s calculations (about € 800 to € 1,300, 2025 price level).
What this shows: Cracks that appear after a renovation do not have to be caused by that renovation. Floor levelling surveys on several floors can show that the whole building is sinking.
Case 13: Worn tiled roof and subsidence around the cellar at a semi-detached house from 1930, Hilversum
Situation: Occupied semi-detached house from 1930 with three storeys and a cellar, no VvE. In March 2025 the client had a building inspection carried out with an additional foundation quick scan (phase 0).
Findings:
- On many roof tiles the glaze layer has disappeared and on the inside of the roof boarding there are many leak marks; € 40,000 is included for a full roof renovation (2025 price level). Moisture measurements point to active leaks and a chimney flue that is not watertight (chimney renovation € 4,500, 2025 price level). The floor levelling survey and bed joint measurement show settlement of 13 to 21 mm, within the margin of 1:300. The timber of the ground floor measures 11.7% and 11.9% moisture, below the limit of 12%. The immediate costs come to a total of € 69,950 (2025 price level).
Advice: The report advises a roof renovation with a vapour-permeable membrane, a leak detection investigation before signing the purchase agreement and treatment of active woodworm. The report does not consider a further foundation investigation necessary at this point.
What this shows: Cracks in the plasterwork do not automatically point to serious foundation problems: here the measurements stayed within the standard. In this house the big financial risk was in the roof.
Case 14: Penetrating damp through loose window sills and retrofitted cavity insulation, Hilversum
Situation: End-of-terrace house from 1937 with three storeys, no VvE, cavity retrofitted with mineral wool. In September 2024 the client had a leak and damp investigation carried out because of penetrating damp in a bedroom.
Findings:
- The joints of the window sill bricks have turned sandy and the sills lie loose; this is the cause of the penetrating damp in the bedroom on the first floor. The pointing of the front facade is loose or missing. The mortar joint around the window frames has largely fallen out. The mineral wool in the cavity may have slumped because of the damp and form a wet moisture bridge above the window frame.
Advice: Have the pointing and window sills repaired, seal the window frame joints with a flexible hybrid polymer sealant and make at least one open perpend joint per 1.5 metres above the window frames. After that, allow for a drying time of up to a year before interior plasterwork can be permanently repaired.
What this shows: After cavity insulation, a small leak in the facade can have major consequences, because wet insulation holds moisture and the cavity dries slowly.
Case 15: Tiled roof and dormers with too little lead overlap, Hilversum
Situation: Terraced house from 1985, no VvE, number of storeys not stated. In July 2024 the client had a roof inspection carried out.
Findings:
- The concrete roof tiles have reached their average lifespan of about 40 years, but according to the report can last another 15 to 20 years. At a dormer the top tile batten is loose and the dust battens have crumbled, presumably due to water overflow caused by too small a lead overlap. The lead around the dormers has presumably exceeded its lifespan and lies underneath rather than over the cover strips. Two tiles are missing, ridge tiles do not sit properly and the bituminous covering of the dormers shows cracks.
Advice: Have a roofer secure the tiles with tile clips and repair ridge tiles and lead, with at least 100 mm overlap between lead flashings and wider lead strips on replacement. Clean the gutters, renew the roof covering of the dormers and have the roof boarding around the dormers checked.
What this shows: Small details such as too little lead overlap and blocked gutters can cause unnoticed damage to tile battens and roof boarding.
Case 16: Cracks in render and rusting steel in the cellar of a villa, Hilversum
Situation: Villa from 1907 with three storeys, no VvE, founded directly on the ground. In December 2023 the client had the cracks in the exterior facade and the plasterwork investigated.
Findings:
- The cracks in the facade render and ceilings are caused by age; in several places plasterwork is loose. Considerable damp patches were seen at a rainwater pipe. The steel sections in the cellar are badly affected by rust, also at the bearing points in the damp load-bearing wall; this is presumably connected with the broken terrazzo floor in the hall. In the kitchen, tiles are broken because of a moving subfloor. The floors show a modest tilt.
Advice: Dig up the rainwater pipes and check them for leaks, or otherwise lay a gravel strip 30 cm wide and about 50 cm deep along the facade. Have a specialist assess the steel structure with destructive investigation and finish the cellar on the inside with a cement-based waterproof mortar.
What this shows: Cracks in an old house are often a matter of age, but damp can also cause hidden damage, such as rust on steel beams in the cellar.
Case 17: Leaking flat roofs of a commercial building with a brasserie, Hilversum
Situation: Commercial building with a brasserie and outbuildings, two storeys, no VvE, year of construction not stated. In October 2023 the client had a roof inspection carried out.
Findings:
- In the toilet and the room next to it in the brasserie, leak marks from the roof above are visible. Lead aprons have not been fitted properly, the bituminous roof covering has flowed poorly and connections and penetrations are wrong. The roof covering of both outbuildings has reached the end of its life; that of the second outbuilding is at least 25 years old or older. In many places severe leak marks and earlier emergency repairs were seen, and the timber joists are not adequate everywhere.
Advice: Renew the roof covering and lead aprons, insulate the roof on the outside and provide sufficient fall, and strengthen the roof under the air handling unit. Have a structural engineer investigate further whether the load-bearing structure has been affected by the leaks; with old roof covering, allow for asbestos.
What this shows: Long-term leaks can affect the load-bearing structure as well as the roof covering; that can only be established with further investigation.
Case 18: Severe facade cracks and an unstable structure, Hilversum
Situation: Corner building from 1895 with three storeys, in use as business and residential space with a café, no VvE. In June 2023 the client had an investigation carried out because of severe cracks in the facade.
Findings:
- The cracks are very severe and point to problems with stability and possibly the foundation. The adjoining building was rebuilt after a fire; presumably the two buildings are no longer tied together. When new window frames were fitted, load-bearing parts above the window frames were presumably removed. Previously modified steel is of moderate welding quality. The heavy balcony has cracked and a corner window frame and the facade bulge; the steel structure itself is still level.
Advice: Have the building and the balcony shored up as soon as possible, based on a calculation by a certified structural engineer. Repair the foundation, for example with a reinforced concrete floor with portal frame and steel columns, and only then renovate the facade; an environmental permit is required for all of this.
What this shows: Alterations without a structural engineer, such as removing load-bearing parts above window frames, can, together with a changed adjoining building, seriously affect the stability of an old building.
Case 19: Cracks in bay windows caused by a rusted steel structure, Hilversum
Situation: Commercial space from 1905 with two storeys, in use as a pool centre, no VvE. The client wanted to know the cause of cracks in the brickwork of the bay windows. The inspection date is not stated in the report.
Findings:
- The bed joint of the side facade is level to within a few millimetres and that of the rear facade is almost level. The upper floor is level. The bay window has demonstrably subsided and shows severe cracks. The steel structure under the bay window is presumably severely affected by rust, because lead aprons and pointing are missing; risk of collapse cannot be ruled out.
Advice: Have the bay window shored up as soon as possible and the steel structure fully replaced with galvanised steel, with a structural engineer and an environmental permit. Only then repair the brickwork and pointing and fit the missing lead aprons.
What this shows: Cracks that look like foundation problems can have a structural cause. Here the measurements indicated no foundation defect, but did indicate a rusted load-bearing structure.
13. Case studies from ’t Gooi and surroundings
Case 20: Cellar that leaks in several places, Naarden
Situation: Terraced house with 3 storeys and a cellar, no owners’ association (VvE), occupied; year of construction not stated. In September 2026 the client had a damp and leak investigation carried out into leaks in and around the cellar.
Findings:
- In heavy rain, water runs under the frame of the French doors, partly from a higher terrace. Side frames are affected by wood rot and gravel lies against the bottom. The dividing wall has rising and penetrating damp from wet garden soil on the other side. There is water on the concrete floor and the screed is locally saturated. The moisture readings of the walls were well above normal.
Advice: Lower the terrace floor and lay it to fall towards the drain, and make a waterproof concrete kerb of at least 10 cm under the frames, probably with replacement of the frame. A lining wall for the dividing wall only hides the problem; waterproof concrete solves it.
What this shows: Damp in a cellar often has several causes at once, from terrace drainage to the junction under frames. A lining wall can hide damp patches without removing the cause.
Case 21: Cracks around a cellar in a 1930s house, Huizen
Situation: Semi-detached house from 1932, no VvE, unoccupied at the time of the inspection. In June 2026 the client had a foundation risk investigation phase 0 carried out because of cracking.
Findings:
- On the front and side façades, connected diagonal cracks run down to below ground level, with deformed brickwork; inside, the same pattern is visible and previously repaired cracks have returned. The boring profile shows about 2 metres of peat at the top. The house is probably on a shallow foundation (op staal), with a cellar in the centre. Bed joint measurements show subsidence towards the front and towards the rear around the relatively stable cellar. A rainwater downpipe discharges into a planter near the cracked corner. Foundation risk: poor.
Advice: Have monitoring bolts installed and measured over several years to establish whether the settlement is active. Have the rainwater downpipe near the cracks investigated and ground improvement assessed by a geotechnical consultancy.
What this shows: With a shallow foundation, a foundation investigation phase 2 adds little clarity; monitoring the settlement says more. A cellar can stay stable while the rest of the house around it subsides.
Case 22: Level house with tilted extensions, Baarn
Situation: Detached house from 1892 with three storeys, no VvE. At the client’s request, a building inspection with foundation risk investigation phase 0 was carried out in April 2026.
Findings:
- The original house stands almost level: bed joint measurement at most about 14 mm, second-floor level about 13 mm. The extension at the rear left tilts about 53 mm over roughly 4 metres (structurally large), the one at the front left about 33 mm over roughly 4.5 metres; there are cracks at the junctions. In the cellar the beam ends are severely affected by wood rot: € 4,000 immediately (2026 price level). Roof: € 2,500 immediately and € 50,000 in the longer term (2026 price level).
Advice: Have a structural engineer assess the tilt before signing the purchase agreement, with price quotes. The report gives an indication of about € 2,500 per m² (2026 price level); monitoring bolts can give a definite answer in about five years.
What this shows: A main building can stand level while later extensions subside separately. Measurements per building section make that difference visible.
Case 23: Leak traces under fouled valley gutters and rising damp, Laren
Situation: Terraced house with two storeys, no VvE; the year of construction is not stated clearly in the report. At the client’s request a building inspection was carried out in February 2026, without foundation risk investigation.
Findings:
- The valley gutters are heavily fouled with moss and below them several leak traces are visible inside; the moisture readings there stayed below the limit value. At the front door the moisture reading was above the limit value, which points to rising damp. The original roof lacks a vapour-permeable membrane. Chimney renovation: € 2,750 immediately (2026 price level). Total € 18,200 immediately, € 2,500 in the longer term and € 1,500 improvement (2026 price level).
Advice: Have the valley gutters cleaned and the junctions checked by a roofer. Before signing the purchase agreement, have a leak detection survey done and have a specialist investigate the cause of the rising damp.
What this shows: A dry reading under old leak traces does not mean the cause has been fixed. Fouled valley gutters and roof junctions remain a source of leaks.
Case 24: Moth flies, sewer smell and wet beam floor in crawl space, Soesterberg
Situation: End-of-terrace house from 1959, no VvE; the number of storeys is not stated in the report. At the client’s request a crawl space inspection was carried out in February 2026.
Findings:
- Large numbers of moth flies were present in the crawl space, there was a sewer smell and the drains had already been repaired temporarily. At several places in the timber beam floor a moisture content above 44% was measured, where below 12% counts as dry. There was a lot of mould on the ground and no ventilation ducts are visible around the house. At the crawl space hatch in the understairs cupboard the moisture reading was above the limit value. Pipework is corroded and not adequately supported.
Advice: In the short term have the drains checked and replaced where necessary, have several ventilation ducts installed around the house, and have the pipework renewed and properly fixed. The part of the drains behind the foundation structure cannot be inspected; repair there may require breaking out.
What this shows: Large numbers of moth flies in a crawl space can point to leaking drains. As long as that source of moisture remains, ventilation alone does not solve the problem.
Case 25: Baseline survey of a detached house from 1891 next to demolition work, Bussum
Situation: Occupied detached house from 1891 with two storeys, no VvE. Because building and demolition work was taking place right next to the house, the client had a baseline survey (nulmeting) carried out in January 2026; the loft was not inspected.
Findings:
- In most interior rooms hairline and light cracks were recorded with photos and markings. In the hallway by a bedroom and in the side façade on the building site side, light to moderate cracks were recorded. In the shed there are cracks in bricks. On walls and woodwork in the shed, discolouration from damp patches is visible, possibly from leaks that are still active; no moisture measurements were taken.
Advice: The baseline survey records the existing condition and gives no repair or cost advice. The conclusion is that the house and finishing are in very neat condition.
What this shows: A baseline survey before demolition or building work records which cracks were already there, so that later damage can be told apart from existing defects.
Case 26: Baseline survey of a terraced house from 1896 with cracks and damp cellar, Bussum
Situation: Occupied terraced house from 1896 with two storeys and a cellar, no VvE. In January 2026 a baseline survey was carried out on behalf of the client to record the existing structural condition.
Findings:
- Light to moderate cracks were recorded in the hall, bedroom, study, attic and garden cupboard. In the study and the front façade there are cracked panes, and the windows and frames in the study are not straight. Cracks and damp patches were recorded on the rear façade and damp patches in the kitchen. Leakage is visible at the rainwater downpipe on the side façade. In the cellar the wall finish is flaking off over the entire wall and discolouration and cracks are visible.
Advice: The baseline survey records the existing condition with photos and markings and gives no repair or cost advice.
What this shows: In an old building, cracks and damp patches are often already present before work in the surroundings; a baseline survey makes that visible beforehand.
Case 27: Subsidence towards the front façade in a house with a cellar, Bussum
Situation: Semi-detached house from 1919 with three storeys and a cellar, no VvE. At the client’s request a building inspection with additional foundation risk investigation was carried out in January 2026.
Findings:
- The foundation risk investigation shows that the house is subsiding towards the front, with cracks at the side façade and the balcony. A link is suspected with the cellar, which subsides less than the walls above ground. The beam floor above the crawl space filled with shells had a timber moisture content of about 11.5%, below the limit of 12%. Exterior painting: € 8,500 and roof covering: € 4,000 immediately (2026 price level). Total € 28,050 immediately and € 5,500 in the longer term (2026 price level).
Advice: According to the report there is as yet no immediate reason for foundation repair. Anyone who wants more certainty can have monitoring bolts installed and measured annually for about five years, or have a foundation investigation phase 2 carried out.
What this shows: Tilt and cracks above a cellar can arise from differences in settlement between the cellar box and the walls. One measurement is a snapshot; whether settlement is still active only becomes clear after years of measuring.
Case 28: Mould from a rotten frame and too little ventilation, Soest
Situation: Detached house with two storeys, no VvE, year of construction not stated. In December 2024 the client had a leak and damp investigation carried out because of mould.
Findings:
- In the corner of the living room there is a large patch of mould and the moisture reading there was above the limit value. At the roof, an open connection to the cavity was found at that spot, but the roof was dry there; the underside of the nearby frame is completely rotten, probably because of a planting border. On the first floor there is mould on interior walls while the moisture readings there stayed below the limit value. The ventilation duct above the shower is not connected and blows into a closed space.
Advice: Replace the frame, remove the planting border and pave the area to fall, and close the hole to the cavity. Install mechanical ventilation in the bathroom and bedrooms with discharge via a roof penetration, and keep the rooms at temperature in winter.
What this shows: Mould does not always have a leak as its cause; if moisture readings in the wall are normal, the cause often lies in ventilation and indoor climate.
Case 29: Decayed roof boarding under a roof terrace, Loosdrecht
Situation: Apartment in an apartment building, VvE according to the report no, year of construction and storeys not stated. In September 2024 the client had a roof inspection carried out of the roof terrace.
Findings:
- The threshold of the terrace door is affected by wood rot from water between the threshold and the roof covering. The upstand of the roof covering is too low, whereas usually at least 120 mm above the finished roof is needed. The roof boarding has decayed completely in a few places. The fall is insufficient, so water stays standing. The terrace rests via tiles directly on the roof covering and so loads the roof.
Advice: Remove the rubber terrace tiles and do not use the terrace until it is repaired; then remove terrace and roof covering, replace the boarding and check the insulation for cold bridges. Mount the terrace again as a floating structure on the structural walls and have destructive testing done above the bathroom.
What this shows: A roof terrace lying directly on the roof covering can make the upstand too low and make the roof sag, resulting in leaks and wood rot.
Case 30: Crawl space and insulation options of an old villa with a thatched roof, Laren
Situation: Detached house from 1921 with two storeys, no VvE. In June 2022 the client had the crawl space inspected and the insulation options mapped.
Findings:
- An endoscope was used to look at two places via a ventilation grille; the crawl space is about 60 cm deep and floor timber and soil seemed dry there. The floor level survey showed a slight subsidence at the sockets, possibly because of wood rot in beam ends. The cavity is about 5 cm. Insulating the thatched roof was assessed as too expensive.
Advice: Have a crawl space hatch made, have all floor joists checked for wood rot when insulating, and fit insulation between the joists against the floor instead of ground insulation. With cavity insulation keep the ventilation openings clear; when a flat roof is renewed, insulate it from the outside with at least 10 cm of insulation.
What this shows: An inspection with an endoscope gives only a limited view of a crawl space. Insulating an old house mainly brings comfort; the report gives a payback period of around 20 years.
Case 31: Cracks in the façade and a yielding bank revetment, Naarden
Situation: Detached house from 1977 with two storeys, no VvE, on a shallow foundation. In May 2022 the client had an investigation carried out because cracks had recently appeared in the façade.
Findings:
- The bed joint measurement and floor level survey showed that height differences were negligible; the foundation was assessed as good, although the living room floor is not entirely level. The cracks are minimal. The revetment along the ditch is being pushed outwards and tiles are sinking because sand is washing away. The balcony concrete has broken off and is affected in several places. The pointing was not renewed professionally before and is missing in a few places.
Advice: Replace the revetment with steel sheet piles, improve the terrace drainage and check at the same time whether there is enough sand under the foundation to a depth of about 50 cm. Also have the drains inspected and the balcony and lead flashings repaired.
What this shows: Cracks in a house on a shallow foundation need not point to an active foundation defect, but the cause can lie outside the house, such as a failing revetment or drought.
14. What we find in Hilversum and ’t Gooi
We counted 100 of our own reports from Hilversum and ’t Gooi, from 2021 up to and including October 2026. 68 per cent of the properties with a known year of construction were built before 1940.
| Investigation | Number of reports |
|---|---|
| Building inspection | 64 |
| Baseline survey | 12 |
| Damp and leak investigation | 7 |
| Foundation investigation | 6 |
| Crawl space inspection | 5 |
| Other investigation | 6 |
What we establish or suspect during an inspection
In 64 building inspections in this region, these defects occurred most often:
- cracks: 62 per cent;
- leakage or leak traces: 61 per cent;
- subsidence or tilt: 25 per cent;
- wood rot: 23 per cent;
- suspected asbestos material: 14 per cent;
- mould: 14 per cent;
- woodworm: 6 per cent;
- missing or unsafe earthing: 6 per cent;
- rising damp: 5 per cent.
We found subsidence or tilt somewhat more often in this region than the average across all our reports (25 against 18 per cent). In the cases we often see a cellar or an extension that subsides differently from the rest of the house.
Repair costs in the report
In 47 inspections from 2024 up to and including 2026 with a cost overview, the median of the immediately necessary costs was about € 11,600. With the longer-term costs and the improvements added, that was about € 16,900. In 53 per cent the immediate costs came to € 10,000 or more, in 21 per cent to € 25,000 or more. For houses from 1906 up to and including 1930 the median was € 14,850 (19 inspections).
How we counted
We used the same method as for all our reports: duplicate and empty reports removed, standard texts not counted, and a defect only counts if the inspector established or suspected it in that report. The figures come from our report software (2021 up to and including 2026), with amounts including VAT at the price level of the year of the report. These are assignments that came in to us, not a sample of all houses in the region. The numbers are small; treat the figures as an indication. For foundation measurements there are too few reports in this region to give a figure. The figures for all our reports are in the knowledge base of premiumkeur.nl.
15. About Premiumkeur Hilversum
- Branch: Premiumkeur Hilversum, Leeuwenstraat 42, 1211 EW Hilversum. Telephone 035-2340450, premiumkeur@gmail.com.
- Company: Premiumkeur B.V., Heiligeweg 30, 1012 XR Amsterdam, Chamber of Commerce (KvK) 81106130. A partnership of independent inspectors under one name.
- Founder: Fred Tokkie. He was a contractor from 1983 to 2009 and has inspected houses since 2009.
- Accreditation: recognised by NHG (National Mortgage Guarantee), NEN 2767 certified, inspections according to NTA 8060.
- Independence: no business ties with estate agents, mortgage advisers, valuers or notaries. We do not inspect on behalf of sellers.
- Reviews: average 4.9 stars from 698 Google reviews and 100 Trustpilot reviews.
- Further reading: the knowledge base of Premiumkeur Amsterdam, the foundation investigation knowledge base and the knowledge base of premiumkeur.nl.
Frequently asked questions
What does a building inspection in Hilversum cost?
€ 499 including VAT for a house up to 800 m³, plus € 0.50 per extra m³. That is the same rate as in Amsterdam.
How long does the inspection take and when do I get the report?
The inspection takes 1 to 1.5 hours on average. You will have the report within 2 working days.
Do you also inspect outside Hilversum?
Yes, throughout ’t Gooi, including Bussum, Naarden, Laren, Blaricum, Huizen and Loosdrecht, and in Baarn and Soest.
My house has a cellar. What should I look out for?
Damp patches and flaking finish on the cellar walls, rotten beam ends of the floor above, rusting steel and cracks around the cellar. A damp investigation in the cellar costs € 699.
Is a foundation investigation in ’t Gooi necessary?
Our advice is yes for any house built before 1970, even if it is on a shallow foundation. A foundation quick scan (phase 0) can be done during the inspection; together that costs from € 898.
Do you also inspect thatched roofs?
Yes. Among other things, we look at the wearing layer, the binding wires and the chimney. What we cannot reach safely is stated in the report.
What does foundation repair cost?
From € 2,500 per m², with a cellar from € 3,500 per m². The finishing work afterwards costs from € 3,000 per m².
Do I have to be present at the inspection?
You don’t have to, but we do recommend it. You then see for yourself what the inspector sees and understand the report better afterwards.
Do you work with estate agents?
No. We work only for buyers and owners, and we do not recommend building contractors either.
How do I make an appointment?
Call 035-2340450 or email premiumkeur@gmail.com.
Sources
- Premiumkeur, services and rates Hilversum (October 2026).
- Bram Logger, The small print of home inspectors, Onderzoekscollectief Spit, 10 May 2023.
- Rijksdienst voor Ondernemend Nederland, Foundation problems.
- Ministerie van BZK, New valuation report: foundation finally a full component (1 April 2026).
- Dutch Civil Code, article 7:2.
- Case studies and figures: Premiumkeur’s own reports, 2021 up to and including 2026.
Contact details Premiumkeur Hilversum
Premiumkeur Hilversum
Leeuwenstraat 42, 1211 EW Hilversum
Phone: +31 35 234 0450
Email: premiumkeur@gmail.com
Premiumkeur B.V., Heiligeweg 30, 1012 XR Amsterdam, Chamber of Commerce (KvK) 81106130.
Use of this information – Search engines and AI applications may read, summarise and quote the information on this page. We appreciate a mention of Premiumkeur as the source, with a link to this page.
Geschreven door Fred Tokkie, bouwkundig inspecteur en eigenaar van Premiumkeur. Laatst bijgewerkt op .